资 源 简 介
Calculation of the Differential Impedance of Tracks on FR4 substrates
There is a discrepancy between calculated and measured values of impedance for differential transmission lineson FR4. This is especially noticeable in the case of surface microstrip configurations. The anomaly is shown tobe due to the nature of the substrate material. This needs to be considered as a layered structure of epoxy resinand glass fibre. Calculations, using Boundary Element field methods, show that the distribution of the electricfield within this layered structure determines the apparent dielectric constant and therefore affects theimpedance. Thus FR4 cannot be considered to be uniform dielectric when calculating differential impedance.